-
-
-
-
-
-
-
-
-
-
-
Hologic Discovery with AP spine and proximal femur, scan comparison, supine lateral BMD. (Delphi SL or A), forearm and whole body. Reporting Options The Discovery has the most advanced remote interpretation and reporting software available, including wireless networking, speech recognition compatibiity, QDR mobility (read scan anywhere anytime), the IRIS connectivity suite integrates with existing healthcare information systems.
-
The Leica Wild OHS swiss design. Counter pivot arm for smooth fluid movement. Inclinable binocular. 10x/22b Eyepieces. Motorized focus & zoom. Fiber-optic illumination. Spare bulb & dust cover available. Pistol control. Innovative technology. Call today for more info!
-
The Leica Wild M680 surgical microscope has two independent zoom systems and two independent internal focusing systems, through a single objective lens. Projecting both views through a single lens allows the surgeon to look closely into deep incisions. The system can provide a unique collaborative environment between the surgeon and assistant. Each user has his or her own hand switch or foot pedal to adjust magnification and focus independently.
-
The Zeiss 1FC features 5 Step magnification changer. Straight binocular. 250mm Objective lens. 10x/22b Widefield eyepieces. Manual fine focus. Inclined coupling. SuperLux 40 Xenon Light Source
-
The Zeiss PhotoColposcope features: 4 Working joints for versaitility. Great for space constrained offices. 4 Locking casters. Easily transportable. Great image quality. Manual zoom & focus. Versatile design. Long reach swing arm. Distributed balance. Improved lighting.
-
The Smith Nephew Dyonics 750 DyoCom features: Video Imager: 1/2″ high resolution CCD Resolution: 500 lines Signal-to-Noise: 47dB Scanning System: NTSC color format: 525 lines, 60 fields, 30 frames Video Output: 1 volt P-P, NTSC into 75 ohms RGB Output: 1 volt P-P, R-G-B & Sync into 75 ohms Y/C Output: Combined luminance / chroma signal into 4 pin mini Din plug Minimum Illumination: 5 lux AC Leakage Current: Less than 25 microamps Power Requirements: 110-120 VAC, 60 Hz, 50 Watts Operating Temperature: 32 degrees F (0 degrees C) to 120 degrees F (48.9 degrees C) Camera Head Dimension: 1.5″ diameter x 1.7″ length Camera Head Weight: 12.8 oz. CCU Dimensions: 3.4″ H x 16″ W x 11″ D CCU Weight: 7.5 lbs. Camera Cable: 12′ cable with edge card type connector system Lens Mount: Standard C-Mount 1″-32 UN-2A Focal Distance: 17.5mm
-
Olympus Visera CLV S40 features: Ideal for Endoscopic TV oberservation connectable with conventional telescopes, fibrescopes, Visera videoscopes and OES fibrescope. Adaptable to all endoscopic procedures: The powerful and convenient CLV-S40 makes endoscopic procedures easier then ever. Powerful & Long-Life 300-Watt Xenon Lamp This high-quality xenon lamp provides an illumination which is ideal for endoscopy, allowing observation in deep sites or advanced techniques. Plus, it can be used continuously for 500 hours (in intermittent use, lamp life time may differ slightly). Automatic Brightness Control When the CLV-S40 is connected via a light guide cable to video systems such as the Visera system; brightness can be automatically adjusted, saving your time and energy. Standby Illumination can be set to standby using a switch on the front panel or a remote switch on the camera head. Intensity-Mode Memory With Intensity-Mode Memory, when the CLV-S40 is turned off in the high intensity mode, it will still be in that mode when turned back on. This is also true for the normal intensity mode. Easy-to-See Front Panel You can easily adjust brightness and power with buttons and switches on the front panel. Click here for VISERA
-
Dyonics Smith Nephew 10mm 0° Laproscope. Many other surgical endoscopes available. Call (774) 888-1000 for additional inventory.
-
Linvatec 4mm 0° Hysteroscope. Many other surgical endoscopes available. Call (774) 888-1000 for additional inventory.
-
As the third generation in Stryker’s HD 3-Chip camera line, the Stryker 1288 HD Camera features a 1920x1080p resolution and nine specialty settings, resulting in optimum color resolution and brightness. A groundbreaking new development of this camera is its ability to allow for wireless transmission capabilities in the OR when used with the Stryker WiSe wireless flat panel monitor. With the WiSe technology, OR clutter will be reduced with the elimination of the 30 ft. DVI cable to the secondary flat panel monitors in the room. Additional benefits of the 1288 HD 3-Chip Camera include four fully programmable buttons on the camera head, giving the surgeon the command to control the light source settings directly from the camera head. Also, by allowing for backwards compatibility with past generation digital capture devices, scopes and various flat panels, the 1288 HD 3-Chip Camera continues to offer new solutions for improved visualization within the OR. 1920x1080p resolution Improved clarity, focus and sharpness Wireless transmission capabilities when used with the Stryker WiSE wireless monitor Touch screen LCD interface Fully programmable camera head buttons
-
The Linvatec IM3301 features 480p Progressive scan output. 4th Generation autoclavable camera head. Multiple pure digital outputs. Electronic zoom. Programmable presets. Programmable remote camera head buttons. Outstanding light sensitivity. New ergonomic design. 800 Line horizontal resoluton. 10ft Cable.
-
The new quick-lock mechanism for secure camera and telescope connection, together with outstanding optical performance and durable mechanical design, make Olympus TrueView II arthroscopes the instruments of choice for arthroscopic procedures. Features: 115º wide angle field of view Automatic ’quick-lock’ connector for secure and fuss-free connection Distortion-free image Scratch-proof sapphire glass distal window Long-term autoclavability 4.0mm or 2.7mm diameter
-
Storz 11274A ureteroscope. Many other flexible endoscopes available. Call (774) 888-1000 for additional inventory.
-
Fujinon EB 250S G5 bronchoscope. Many other flexible endoscopes available. Call (774) 888-1000 for additional inventory.
-
Olympus AF 14 angioscope. Many other flexible endoscopes available. Call (774) 888-1000 for additional inventory.
-
-
-
-
PC-based Edan ECG SE 1010 provides you an affordable and portable 12-channel ECG solution with powerful data analysis functions. Optional advanced analysis functions secure clinical accuracy and maximum decision-making efficiency. Features: Simultaneous 12 Leads acquisition handheld design Real-time ECG waveforms display on PC screen Auto /Manual measurement and interpretation WORD, PDF and JPG format reports transferred via E-mail Optional advanced analysis functions: Timed vectorcardiogram, VCG(3D), SAECG,QT interval dispersion, HRT, HFECG, Frequency Spectrum cardiogram 30s-900s HRV (heart rate variability) sample and analysis Stress test and exercise blood pressure monitor (option)
-
Promo !
The ConMed Excalibur PC Plus and Power Plus models are available in bipolar or monopolar with cutting and coagulation. The Excaliburs are multi-purpose electrosurgical generators. Microprocessor control provides the user with safety and control. On the cut setting, these units provide 300 watts of output. A bipolar footswitch is available but optional as are rolling carts.
-
The Alaris Gemini PC IV features: Operating principle: Linear Peristalsis. Dimensions 12.0″ x 14.75″ x 7.5″ (30.5 cm x 37.5 cm x 19.1 cm) Weight 26.5 lbs. (12.0 kg) Power Requirements 90 – 132 VAC, Current draw 0.1A nominal (0.36A maximum), 10 watts, fused at 0.4A, 50/60 Hz, 3 wire, single phase Battery Operation With new, fully charged batteries, approximately 4 hours with All four channels infusing as primary infusion at 125 ml/hr before a “BATTERY DISCHARGED” message. Electrical Leakage Less than 100 microamps Rate Selections 0.1-999 ml/hr. Note: Recommended maximum rate in the Controller Mode is 500 ml/hr. Volume-To-Be-Infused Selections 0.1-9999 ml KVO (Keep Vein Open Rate 1 ml/hr if set rate is 1 ml/hr or above; or set rate, if rate is 0.9 ml/hr or below. Occlusion Pressure Controller mode Container height ±12″ (±30 cm) Pump Mode 10±2 psi (517 ± 103 mmHg) for rates above 30 ml/hr. For rates of 30 ml/hr and below, the occlusion pressure will be less than 10 psi, an is rate-dependent. Selectable mode 25 – 517 mmHg in 25 mmHg increments to 500 mmHg.