EQUIPMENT

/EQUIPMENT
  • The HP Philips Codemaster XL high-performance, high-speed defibrillator charges from 0 to 360 joules in under 5 seconds, plus it offers a variety of advanced options easily customized to meet the needs of your unit. The CodeMaster XL+ Defibrillator by HP is a flexible choice for high-use areas of the hospital including operating rooms, intensive care units, cardiac care units, and emergency departments, as well as for clinics and ambulatory surgery centers.
  • ALARIS GEMINI PC IV

    $50.00$80.00
    The Alaris Gemini PC IV features: Operating principle: Linear Peristalsis. Dimensions 12.0″ x 14.75″ x 7.5″ (30.5 cm x 37.5 cm x 19.1 cm) Weight 26.5 lbs. (12.0 kg) Power Requirements 90 – 132 VAC, Current draw 0.1A nominal (0.36A maximum), 10 watts, fused at 0.4A, 50/60 Hz, 3 wire, single phase Battery Operation With new, fully charged batteries, approximately 4 hours with All four channels infusing as primary infusion at 125 ml/hr before a “BATTERY DISCHARGED” message. Electrical Leakage Less than 100 microamps Rate Selections 0.1-999 ml/hr. Note: Recommended maximum rate in the Controller Mode is 500 ml/hr. Volume-To-Be-Infused Selections 0.1-9999 ml KVO (Keep Vein Open Rate 1 ml/hr if set rate is 1 ml/hr or above; or set rate, if rate is 0.9 ml/hr or below. Occlusion Pressure Controller mode Container height ±12″ (±30 cm) Pump Mode 10±2 psi (517 ± 103 mmHg) for rates above 30 ml/hr. For rates of 30 ml/hr and below, the occlusion pressure will be less than 10 psi, an is rate-dependent. Selectable mode 25 – 517 mmHg in 25 mmHg increments to 500 mmHg.
  • Promo !
    The ConMed Excalibur PC Plus and Power Plus models are available in bipolar or monopolar with cutting and coagulation. The Excaliburs are multi-purpose electrosurgical generators. Microprocessor control provides the user with safety and control. On the cut setting, these units provide 300 watts of output. A bipolar footswitch is available but optional as are rolling carts.
  • PC-based Edan ECG SE 1010 provides you an affordable and portable 12-channel ECG solution with powerful data analysis functions. Optional advanced analysis functions secure clinical accuracy and maximum decision-making efficiency. Features: Simultaneous 12 Leads acquisition handheld design Real-time ECG waveforms display on PC screen Auto /Manual measurement and interpretation WORD, PDF and JPG format reports transferred via E-mail Optional advanced analysis functions: Timed vectorcardiogram, VCG(3D), SAECG,QT interval dispersion, HRT, HFECG, Frequency Spectrum cardiogram 30s-900s HRV (heart rate variability) sample and analysis Stress test and exercise blood pressure monitor (option)
  • Datascope Anestar Fresh gas decoupling. Volume constant ventilation. Automatic compliance compensation. Enhanced ventilator accuracy. Touch screen interface. Adult and pediatric ventilation modes. Integrated warmed breathing system. Manages moisture buildup. Eliminated rainout. Warms patient gasses.